A new phenomenon in the electrical and electronics industry
Protector of three-phase electric motors

With special performance

Easy to install

Adjustable

LCD

Two year warranty

What is Pars load control?

As its name suggests, it controls the ampere current of any type of electric motor, and in the face of overcurrents for any reason, it cuts off the command and prevents electric motors, electric pumps, etc. from burning.

کنترل بار 300 آمپر پارس

Working principles of Pars load control

Parsload supercontroller relay with three internal current transformers measures the current of each channel like pliers ammeters and compares it with the regulated current, and if the current of each line is added, it takes the consumer out of the regulated value of the circuit.

To cover the start time in electric motors that cause a large overcurrent for a short time, an adjustable time interval of ٪ 1 to 30 seconds from the moment of overcurrent to the outage command is considered, so if the overcurrent time is less than When the time is selected, the load control does not show any reaction. Turning on the red light indicates the start of overcurrent and turning off the green light is a sign that the control circuit is disconnected. In this case, the red light stays on until the device resets again.

How to install Pars load super control

Installation of 200 amp load control and 300 amp Pars load control is very simple. It is necessary to connect the phase current-carrying ingots to the ingots before or after the contactor to pass the current and connect the 18 and ph terminals to the control circuit. Place the contactorin series and connect the power supply of the device according to the opposite plan.

نقشه کنترل بار پارس
کنترل بار پارس 300

Pars load super control feature

  • Ready to adjust the flow in the first moments
  • Accurate, safe in all conditions and not affected by ambient temperature
  • Ability to set the time from 0.01 seconds to 30 seconds
  • Wide current range of 20 to 200 and 30 to 300 amps
  • Ability to control the flow with two LEDs and two digital screens Amper and Dely
  • Ability to control and protect all three-phase electric motors, generators from electrical and mechanical overcurrent
  • Has a high-performance electronic circuit without mechanical depreciation
  • Easy and fast installation
  • Two year warranty

Specifications of Pars load super control

Wide current range of 20 axes, unlike non-metals, which due to thermal performance has a long and uncertain reaction time and is dependent on ambient temperature, load control 200 amps and load control 300 amps 200 and 30 to 300 amps Parswith inductive function for current measurement and use of advanced electronic circuits has a quick adjustable reaction time and also ambient temperature in different seasons has no effect on its operation.

  • Super load control of Pars electronic relay over three-phase current
  • Suitable replacement for thermal relays (bimetals)
  • Avoid burning three-phase motors against excessive overload
  • Two-phase connection at any point of the current flow path, even inside the motor itself. Electrical and mechanical disturbances created in the motor and the power wires to it.
  • Protection of generators and power transformers against overload and connection in circuits
  • Use for automation in cases where overcurrent is one of the circuit design parameters.
  • Delay timer by delay button
  • It has an ampere and delay display
کنترل بار پارس 300 آمپر

Return the load control to its original or normal state

After issuing the contactor disconnect command, the device can be returned to normal or normal in two ways:

  1. Using the manual reset button on the load control device
  2. Reset from the control panel by disconnecting the load control power supply circuit for a few moments (if required)

Set the device

We connect the power to the switch. The load control has 2 LEDs, one green means normal and the other red means error or overcurrent.

There are 5 keys on the device, the first 2 keys are to adjust the amp or current of the electric motor, one of them is to increase the amp and the other is to decrease the amp, and the next 2 keys are to set the time in the cut-off command, which is 0.01 if needed. The seconds can be set to 30 seconds, and the next key, which is red, is called the reset key.

After increasing the motor current for any reason, it cuts off the steering circuit and prevents the electric motor from burning. With this key, it is possible to restart the motor. Increase the load control amp to the final level and start the switch to turn on the motor, and the load control can be adjusted while the display is blinking.

It can be set to any amp or whenever it stops. After starting the motor completely with the reduction key, we lower the amp to reach the nominal current of the consumer and at this moment the red LED turns on and the consumer current is controlled by two ampere adjustment keys, based on the display on the control. The load is adjusted and in order for the motor to operate, it must increase the nominal current of the amp by ten percent in order to continue its work, and again, if the amp exceeds the regulating current, it stops the command.

online shopping

Representation form